Cells Per Unit 6
Voltage Per Unit 12
Capacity 12 Ah @ 20hr-rate to 1.75V per cell @25°C (77°F)
Weight Approx. 3.67 kg(8.09 lbs)
Maximum Discharge Current 150A/180A(5sec)
Internal Resistance Approx. 16 mΩ
Operating Temperature Range
Nominal Operating Temperature Range
Float Charging Voltage
Recommended Maximum Charging 3.6A
Current Limit
Equalization and Cycle Service
Self Discharge CSB Batteries can be stored for more than 6 months at
Please charge batteries before using. For
higher temperatures the time interval will be shorter.
Terminal F1/F2-Faston Tab187/250
Container Material ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
Discharge:
Charge:
Storage:
Constant Current Discharge Characteristics Unit:A (25°C,77°F)
GP 12120
Specification
12V 12Ah
Powered by
GP 12120 is a general purpose battery up to 5 years in standby
service or more than 260 cycles at 100% discharge in cycle
service. As with all CSB batteries, all are rechargeable, highly
efficient, leak proof and maintenance free.
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H) Container height (h) Length (L)
100±1 (3.94±0.04) 94±1 (3.7±0.04) 151±2 (5.94±0.08) 98±1 (3.85±0.04)
13.5 to 13.8 VDC/unit Average at
14.4 to 15.0 VDC/unit Average at
CSB-manufactured
VRLA batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
(http://www.csb-battery.com)
by TUV CERT according to ISO 9001,ISO 14001.
The system of manufacturer was certified
F.V/Time 5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V
51.2 33.2 23.9 13.9 8.14 5.90 4.69 3.37 2.24 1.45 1.19 0.62
1.67V
48.2 32.0 23.6 13.7 8.12 5.84 4.62 3.35 2.21 1.44 1.18 0.61
1.70V
46.3 31.6 23.3 13.6 8.08 5.82 4.61 3.32 2.18 1.43 1.17 0.61
1.75V
43.3 30.0 22.6 13.4 8.03 5.77 4.57 3.26 2.13 1.40 1.15 0.61
1.80V
38.8 28.0 21.5 13.0 7.81 5.64 4.48 3.17 2.06 1.37 1.14 0.59
1.85V
34.2 25.3 19.8 12.3 7.51 5.41 4.29 3.03 1.97 1.32 1.09 0.57
F.V/Time 5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V
539 347 268 160 97.9 70.6 55.9 39.6 25.3 16.7 13.8 7.70
1.67V
515 342 265 159 97.7 70.2 55.6 39.3 25.2 16.6 13.7 7.63
1.70V
499 336 262 158 97.0 69.9 55.4 39.0 25.0 16.5 13.6 7.61
1.75V
462 326 256 156 96.1 69.3 54.9 38.5 24.4 16.2 13.4 7.54
1.80V
418 307 243 153 94.8 68.0 53.7 37.7 24.1 15.8 13.1 7.42
1.85V
369 280 221 144 91.6 66.2 52.6 36.3 23.3 15.5 12.7 7.23
25°C (77°F)
25°C (77°F)
25°C (77°F).
-15°C~40°C ( 5°F~104°F)
-15°C~50°C ( 5°F~122°F)
-15°C~40°C ( 5°F~104°F)
25°C±3C (77°F±5°F)
Constant Power Discharge Characteristics Unit:W (25°C,77°F)
RA1308
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.