I2-Thread lead alloy recessed terminal to accept M6 bolt
13.5 to 13.8 VDC/unit Average at 25 (77 )
14.4 to 15.0 VDC/unit Average at 25 (77 )
Cells per unit
Voltage per unit
Capacity
Weight
Maximum Discharge Current
Internal Resistance
Operating Temperatur e Range
Nominal Operating Temperature Range
Float Charging Voltage
Recommended Maximum Charging
Current Limit
Equalization and Cycle Service
Self Discharge
Terminal
Container Material
6
12
150W @ 15min-rate to 1.67V per cell @25
o
C(77
o
F)
Approx.11.75 kg(25.9 lbs)
225A(5sec)
Approx. 7
m
25
o
C±3
o
C (77
o
F±5
o
F)
15A
CSB Batteries can be stored for more than 6 months at
25
o
C (77
o
F). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15
~40 ( 5 ~104 )
Storage: -15
~40 ( 5 ~104 )
Constant Power Discharge Characteristics
Unit:W
(25
,77
)
Constant Current Discharge Characteristics
Unit:A
(25
,77
)
HRL 12150W
12V 150W
Specification
Powered by
HRL 12150W is specially designed for high efficient discharge
application. Its characteristics are high energy density, small
footprint and high discharge efficiency. It can be used for more
than 260 cycles at 100% discharge in cycle service, up to 10
years in standby service.
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H) Container height (h) Length (L)
172.0±2.0 (6.77±0.08) -- 195.6±2.0 (7.70±0.08) 130.0±1.5 (5.12±0.06)
F.V/Time
5MIN 7.5MIN 10MIN 15MIN 20MIN 30MIN 40MIN 50MIN 60MIN 90MIN
1.60V
169 138 116 86.7 69.6 50.4 40.0 33.5 28.9 20.8
1.67V
152 127 107 82.2 66.3 48.4 38.7 32.5 28.6 20.5
1.70V
144 122 103 80.0 64.7 47.5 38.0 32.1 28.4 20.4
1.75V
132 112 96.8 76.0 62.0 45.7 36.8 30.9 27.8 20.0
1.80V
119 104 90.0 71.1 58.4 43.8 35.1 29.8 26.8 19.5
1.85V
107 94.1 82.8 67.0 55.1 41.7 33.6 28.6 25.0 18.6
F.V/Time
5MIN 7.5MIN 10MIN 15MIN 20MIN 30MIN 40MIN 50MIN 60MIN 90MIN
1.60V
1,794 1,479 1,263 968 788 577 463 387 335 244
1.67V
1,624 1,370 1,182 935 753 559 451 386 334 239
1.70V
1,549 1,322 1,143 916 737 548 442 382 332 236
1.75V
1,422 1,234 1,075 877 704 530 428 374 325 231
1.80V
1,302 1,143 1,006 825 675 507 410 361 314 226
1.85V
1,188 1,057 943 773 639 486 396 337 296 222
CSB-manufactured
VRLA batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
(http://www.csb-battery.com)
by TUV CERT according to ISO 9001,ISO 14001.
The system of manufacturer was certified
RA1308
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - HRL 12150W

I2-Thread lead alloy recessed terminal to accept M6 bolt13.5 to 13.8 VDC/unit Average at 25 (77 )14.4 to 15.0 VDC/unit Average at 25 (77 )Cells per un

Seite 2

68Charging ProceduresCharge Voltage(V/Cell)ApplicationTemperature Set Point Allowable RangeMax.Charge CurrentCycle Use25(77 )2.45 2.40~2.50Standby25 (

Kommentare zu diesen Handbüchern

Keine Kommentare